Cleanspace Respirator: CST Ultra Power System (Ultra New)
Advanced Respirator
CleanSpace ULTRA is the latest addition to CleanSpace Technology's range of advanced respiratory protection products: designed for industrial use where water tolerance is required (IP Rating 65). CleanSpace ULTRA is a powered air purifying respirator (PAPR) that offers superior protection against dust; with no hoses or heavy waist-mounted battery packs making it the most comfortable and easiest PAPR in the market. CleanSpace ULTRA is a lightweight and compact PAPR making it easy to wear for extended periods of time. The ULTRA also has the most advanced PAPR technology with optimized fan acoustics for clear communication. With no cumbersome hoses or heavy waist-mounted battery packs, CleanSpace ULTRA is a modern PAPR and the most comfortable and easiest PAPR to use in the market.
- Fresh air – cool, not recycled
- Breath responsive airflow
- Very high protection 99.97% filter efficiency and positive airflow
- Long run time (minimum 12 hours) and high peak airflow: 230 L/min
- Compatible with half/full face masks (sold separately)
- User-friendly modern design: no belts or hoses, few parts and built for tough workplace
- Clips designed for gloved hands
- Fully approved: NIOSH, CE, UKCA and AS/NZS171
- Limited parts and accessories reduces lead times, lost production, downtime
- Ergonomically friendly design
- Reusable, shareable system
- Cost savings vs other PAPR respirators on the market
- Cost savings on comparable filters
- IP-65 Rating: Resistant to dust and liquid ingress
- Suitable for decontamination showers and high water use environments
- 2-Year Warranty
Smartphone APP
Connectivity with CleanSpace SMART app. CleanSpace ULTRA connectivity provides safety and site managers with additional online tools to help to manage safety, compliance, and performance of a respiratory protection program, including battery management, automated Mask Fit Check, and Intelligent Management Filter Technology.
In the Box?
- 1x CleanSpace ULTRA Power System Unit
- 1x PAF-1100 Charger
- 1x CST1019 Neck Support Small
- 1x CST1020 Neck Support Medium
- 1x Carry Bag
- User Manual
Masks and filters sold separately.
FAQs
What is the CleanSpace CST Ultra?
The CleanSpace CST Ultra is a powered air purifying respirator (PAPR) designed for industrial use where water tolerance is required. It offers superior protection against dust and gas airborne hazards without the hassle of hoses or heavy battery packs.
What are the key features of the CleanSpace CST Ultra?
- Lightweight and compact design
- Long battery life (up to 14 hours)
- High airflow (up to 230 L/min)
- AirSensit™ technology for optimized airflow
- Connectivity with the CleanSpace SMART app
- Compatible with half and full face masks
- NIOSH, CE, UKCA, and AS/NZS1716 certified
What are the benefits of using the CleanSpace CST Ultra?
- Improved comfort and ease of use compared to traditional PAPRs
- Enhanced worker safety and protection
- Increased productivity due to reduced fatigue
- Better communication with others due to optimized airflow
Technical Questions
How long does the battery last?
The CleanSpace CST Ultra offers a long battery life of up to 14 hours.
What is the airflow rate of the CleanSpace CST Ultra?
The maximum airflow rate of the CleanSpace CST Ultra is 230 L/min.
Is the CleanSpace CST Ultra waterproof?
The CleanSpace CST Ultra has an IP rating of 65, meaning it is water-resistant and can withstand exposure to water jets.
What type of filters are compatible with the CleanSpace CST Ultra?
The CleanSpace CST Ultra is compatible with 2 filters:
- Filter for particulates only and referred to as the "standard" filter or the CleanSpace CST Particulate Standard Filter for ULTRA (SKU: CST10062) and comes in 3 filters per package
- Combined filter for particulates and gaseous fumes that is referred to as the CleanSpace CST Particulate Combined Filter for ULTRA (SKU: CST1006) and comes in 1 filter per package
How do I charge the CleanSpace CST Ultra?
To charge the CleanSpace CST Ultra, connect the unit to the provided charger. A flashing green LED indicates that the unit is charging.
Usage and Maintenance
How do I know when the battery is low?
The CleanSpace CST Ultra has battery level indicators to inform you of the remaining battery life.
How often should I replace the filters?
Filter replacement depends on the specific work environment and contaminant levels. The good news is the CST Ultra has filter indicator to inform you of the remaining filter life. Please also refer to the user manual for guidance.
How do I clean and maintain the CleanSpace CST Ultra?
Regular cleaning and maintenance are essential for optimal performance. We recommend you use the CleanSpace ULTRA Cleaning & Storage Plug (SKU: PAF-0074) to avoid water entering the inner system during cleaning. Please refer to the user manual for detailed cleaning instructions.
Can I use the CleanSpace CST Ultra with glasses? Yes, a eyeglass adapter is available as an optional item.
Can I use the CleanSpace CST Ultra with a beard? Yes, however, for optimal protection, it is recommended to shave before using the CleanSpace CST Ultra.
Connectivity
What is the CleanSpace SMART app?
The CleanSpace SMART app provides additional features such as battery management, automated mask fit check, and intelligent management filter technology.
Is the CleanSpace SMART app available for both iOS and Android?
Currently, the CleanSpace SMART app is available for Android users. An iOS version is expected to be released in the future.
Videos/Docs
Sizing
All CleanSpace respirators are compatible with a range of facepieces including half and full face masks. The half mask comes in three (3) sizes: small, medium and large. When the wearer does not have the masks to select the different sizes, we recommend using the Mask Size Guide available below to assist users with selecting the right size mask.
When selecting a suitable mask size we provide the following guidance:
- A good fit starts with comfort. The right mask size should be comfortable.
- Positioning the nose piece should not be too high (Avoid sitting close to the corner of the eyes) and not too low (should not sit halfway down the nose)
- The chin cushion should rest slightly under the chin with no gaps
- Women best mask fit is a small or medium mask; Men best mask fit is comfortable in a medium or large mask.
When fitting the CleanSpace respirator, mask size is only one way to achieve a good fit, harness and power unit adjustments are also recommended to ensure the system is comfortable and there is minimum leak.
On narrow faces, the action of pulling on the arms of the mask to tighten it causes the height of the mask to increase. The narrower the face, the more likely a smaller mask will be a better fit. Face should be relaxed when taking measurements.
No set of guidelines can ensure that you have the right size mask for your face. You must confirm the fit performed according to OSHA regulations 1910.134.