CleanSpace HALO PAPR: Top Healthcare Respirator Protection
The best NIOSH-approved healthcare PAPR respirator
Product Description
Best Healthcare PAPR System
The CleanSpace Halo PAPR represents a breakthrough in powered air purifying respirator technology, specifically engineered for healthcare professionals who demand superior protection without compromising comfort or mobility. CleanSpace PAPR system eliminates traditional belts, hoses, and heavy battery packs, integrating everything into a sleek neck-mounted design that weighs less than a typical smartphone. This PAPR pairs seamlessly with the CleanSpace Halo Mask, providing a secure, high-efficiency seal suitable for clinical environments, including surgical settings.
CleanSpace HALO Respirator Key Benefits
-
Enhanced Mobility: No external hoses or belts mean complete freedom of movement during patient care
-
Proven Protection: Clinical studies show median protection factors exceeding 1,000 during real-world healthcare procedures
-
Smart Operation: One-button start with automatic standby mode conserves battery and extends filter life
-
Universal Compatibility: Works seamlessly with prescription eyewear, surgical loupes, and other essential PPE
-
Rapid Deployment: Don and doff in seconds with automatic start/stop functionality
Industry-Specific Applications of CleanSpace HALO PAPR
-
Healthcare respirator: ICU, emergency departments, operating rooms, infectious disease units.
-
Laboratory PAPR: Research facilities, diagnostic labs, and pharmaceutical clean rooms.
-
Emergency PAPR: First responders, decontamination teams, and disaster relief.
-
Long-term Care: Nursing homes, rehabilitation centers, aged care facilities.
Industry-specific uses of PAPR
Healthcare & Medical PAPR
Laboratory & Cleanroom PAPR
Emergency Responder Respirator
Protection from Wildfire Smoke in Healthcare Settings
Technology Highlights
AirSensit™ Technology
Intelligent Power Management
Altitude-Compensated Performance
Rapid Response Airflow
Technical Specifications
| Specification | Details |
|---|---|
Compatibility & Accessories
The CleanSpace HALO respirator for healthcare safety is designed to work seamlessly with a wide range of filters and accessories to meet your specific protection needs.
Compatible Filters
High Capacity HEPA Filters
Extended-life HEPA filtration for demanding healthcare applications with smart chip technology to monitor filter usage and performance.
P3 Particulate Filters
High-efficiency filters removing 99.97% of particles including viruses, bacteria, and aerosols. Essential for healthcare and laboratory environments.
Compatible Masks
| Mask Type | Protection Level | Applications |
|---|---|---|
| CleanSpace HALO Half Mask (S/M/L) | APF 50 | General healthcare, laboratories |
| CleanSpace HALO Full Face Mask | APF 1000+ | High-risk procedures, ICU, infectious disease |
| CleanSpace BioHood | APF 25 | Splash protection, emergency response |
Product Comparison
| Feature | CST Ultra PAPR | HALO PAPR | EX PAPR | WORK Kit PAPR |
|---|---|---|---|---|
| Battery Runtime | Up to 14 hours | Up to 9 hours | Up to 8 hours | Up to 8 hours |
| Weight | 415 g | 350 g | 340-350 g | 540 g |
| Water Resistance | IP65 | IP66 | IP66 | IP66 |
| Peak Airflow | 230 L/min | 230 L/min | 200 L/min | 220 L/min |
| Bluetooth App | Yes | No | No | Limited |
| ATEX Certified | No | No | No | Yes |
Product Videos
CleanSpace® HALO | Cleaning and Storage Plug Use
This video demonstrates the proper use of the CleanSpace® HALO Cleaning and Storage Plug, an essential accessory for maintaining your CleanSpace® HALO Powered Air Purifying Respirator (PAPR) unit.
CleanSpace® Fit Testing Set Up | Half Mask
A step-by-step guide on properly setting up and adjusting your CleanSpace® half mask for fit testing. Learn how to select the right mask, enhance its fit with optional grommets, and ensure optimal performance with key features like one-way valves. We'll demonstrate the removal of the exhalation valve, connecting the head harness, and making necessary adjustments for comfort. Don't forget to check that the respirator is off before testing. For more resources, visit CleanSpace Technology’s website. Stay safe and breathe easy.
CleanSpace® Fit Testing Set Up | Full Face Mask
In this instructional video, we walk you through the setup and fit testing process for the CleanSpace full face mask. Learn how to select the right mask, adjust it for a secure fit, and prepare the sensing ball for optimal performance. We’ll guide you on ensuring the inner mask fits correctly, removing the necessary plugs, and conducting negative pressure testing to identify any leaks. For more resources related to CleanSpace® products, visit our website at www.cleanspacetchnology.com.
-
How long does the CleanSpace Halo battery last?
The CleanSpace Halo provides up to 9 hours of continuous operation on a single charge. Actual runtime varies based on breathing rate, altitude, and filter condition. The quick-charge feature allows top-up charging during breaks to extend usage through 12-hour shifts.
-
What makes the CleanSpace Halo different from traditional PAPRs?
Unlike belt-mounted PAPRs with external hoses, the CleanSpace Halo integrates all components into a lightweight, neck-mounted unit. This eliminates trip hazards, reduces weight by 75%, and provides complete freedom of movement while maintaining superior protection.
-
Is fit testing required for the CleanSpace Halo?
Fit testing requirements depend on your mask choice. The CleanSpace Halo with tight-fitting half or full face masks requires standard fit testing per OSHA regulations. However, when used with loose-fitting hoods, no fit testing is required—making it ideal for users with facial hair.
-
How do I clean and maintain the CleanSpace Halo?
The IP66-rated design allows for complete decontamination with hospital-grade disinfectants. The smooth, sealed surfaces can be wiped down between uses, while masks can be sterilized according to facility protocols. Filters should be replaced based on the smart chip indicators or when breathing resistance increases.