Philips HeartStart OnSite AED (M5066A) - Philips AED

SKU: M5066A-2
Regular price $1,465.00
Free Shipping on all U.S. Orders.
Description
Benefits
Specifications / Compatibility
How to Use
Certifications
Compliance
Ideal Setting
Warranty

What's Included:

  • HeartStart OnSite AED M5066A - Main defibrillator unit
  • M5070A Long-Life Battery - Pre-installed, 4-year life
  • M5071A Adult SMART Pads Cartridge - Pre-connected, ready to use
  • Standard Soft Carrying Case - Portable, durable protection
  • Quick Setup Guide - Get started in minutes
  • Owner's Manual - Comprehensive instructions
  • Quick Reference Guide - At-a-glance emergency procedures
  • Maintenance Booklet - With expiration date tags
  • 8-Year Warranty - Industry-leading protection

Philips HeartStart OnSite AED

The Philips HeartStart OnSite AED (M5066A) is a professional-grade automated external defibrillator designed for the ordinary person in extraordinary moments. This FDA-approved AED for sale provides clear, calm voice instructions that guide you step-by-step through the entire rescue process—from pad placement to performing CPR—making it ideal for workplaces, schools, gyms, and public spaces where trained medical personnel may not be immediately available.

With its proven SMART Biphasic therapy technology, the Philips OnSite AED delivers effective treatment for sudden cardiac arrest with an industry-leading 8-year warranty. The device conducts automatic daily, weekly, and monthly self-tests to ensure rescue-readiness and features a Ready light indicator for instant confidence. Whether you're purchasing your first AED or upgrading your emergency response equipment, the Philips HeartStart OnSite AED offers the reliability and ease-of-use that saves lives.

Key Highlights:

  • Clear, calm voice instructions guide you through each step
  • Automatic self-testing ensures device is always ready
  • 8-year manufacturer warranty on the AED unit
  • Lightweight at only 3.3 lbs with battery and pads
  • IP21-rated for dust and drip protection

Why Choose the Philips HeartStart OnSite AED?

1. Designed for Confidence in Critical Moments

The Philips OnSite AED is specifically engineered for first-time users with little or no training. From the moment you open the device, clear voice prompts guide you through every critical step, ensuring you can deliver life-saving treatment confidently and quickly.

Benefits:

  • Reduces panic and confusion during emergencies
  • No prior medical training required
  • Voice coaching walks you through pad placement, shock delivery, and CPR
  • Built-in metronome guides CPR compression rate

2. SMART Biphasic Therapy Technology

The HeartStart OnSite AED features Philips' clinically proven SMART Biphasic waveform technology that automatically adjusts the defibrillation energy based on the patient's impedance, delivering effective treatment across a wide range of patients.

Benefits:

  • Proven effective in treating sudden cardiac arrest
  • Adjusts therapy to individual patient needs
  • Used by emergency medical professionals worldwide
  • Delivers 150 joules of energy for adult patients
  • 50 joules for pediatric patients (with optional infant/child pads)

3. Always Ready When You Need It

The OnSite AED performs rigorous automatic self-tests daily, weekly, and monthly—testing the battery, internal circuitry, and pads readiness. The Ready light provides instant visual confirmation that your AED is prepared for an emergency.

Benefits:

  • Peace of mind with automatic readiness checks
  • No manual testing required
  • Visible Ready indicator light
  • Alerts you if service is needed
  • Minimizes maintenance requirements

4. Quick Shock Delivery Saves Lives

Time is critical during sudden cardiac arrest. The Philips OnSite AED can deliver a shock in as little as 8 seconds after the end of a CPR interval, with typical shock-to-shock time of less than 20 seconds.

Benefits:

  • Faster treatment improves survival rates
  • Quick analysis of heart rhythm
  • Rapid shock delivery when needed
  • Minimal interruption to CPR
  • Every second counts—this AED responds fast

5. Pediatric Capability with Optional Pads

While the HeartStart OnSite AED comes ready for adult use, it can be easily adapted for infants and children under 8 years or 55 lbs by using the optional Infant/Child SMART Pads Cartridge (M5072A). No switches or settings to change—just replace the pads.

Benefits:

  • Protects people of all ages
  • Simple pad swap for pediatric use
  • Automatic energy adjustment for children
  • Essential for schools, daycare centers, and family venues
  • One device serves your entire community

6. Durable, Portable Design

Weighing just 3.3 pounds with battery and pads installed, the OnSite AED is highly portable and protected with an IP21 rating against dust and water drips. The included carrying case makes transportation and storage simple.

Benefits:

  • Take it anywhere—office, field, venue
  • IP21 rating protects against environmental factors
  • Compact design: 7.4" x 8.3" x 2.8"
  • Fits in standard AED wall cabinets
  • Durable construction for years of reliable service

7. Industry-Leading Warranty & Support

Philips stands behind the OnSite AED with an impressive 8-year warranty on the device, 4-year warranty on the battery, and pads warranted until their expiration date. This comprehensive coverage demonstrates Philips' confidence in their life-saving technology.

Benefits:

  • 8-year AED warranty (best in industry)
  • 4-year battery warranty
  • Pads covered until expiration
  • Access to Philips' expert support team
  • Protected investment in safety
  • Simple to Operate: Turns on with an easy-to-use pull handle, ensuring readiness for emergency situations.
  • Guided Audio Instruction: Provides clear voice prompts that assist users in performing CPR and using the AED.
  • SMART Biphasic Therapy: Delivers effective yet safe shocks, minimizing risk to fragile hearts.
  • Built-in Self Test: Conducts daily checks, ensuring the device is always ready for use.
  • Quick Shock Feature: Reduces time between CPR and shock delivery, greatly enhancing the chances of survival.
  • Integrated SMART Pads: Automatically adjust instructions based on application to the patient, aiding user-response accuracy.
  • Visual Queues: Icon-driven operation facilitates easy understanding, even for non-English speakers.

Philips HeartStart OnSite AED (M5066A) Technical Specifications

Physical Specifications

Specification Details
Model Number M5066A
Dimensions (AED) 7.4" W x 8.3" D x 2.8" H (19 cm x 21 cm x 7.2 cm)
Weight (with battery & pads) 3.3 lbs (1.5 kg)
Weight (without battery & pads) 2.4 lbs (1.0 kg)
Protection Rating IP21 (Dust and drip protected)
Carry Case Dimensions 9.5" W x 8.5" H x 4.8" D (24 cm x 21 cm x 12 cm)

Therapy Specifications

Specification Details
Waveform SMART Truncated Exponential Biphasic
Energy Adjustment Automatically adjusts based on patient impedance
Adult Defibrillation Peak current: 32 A (150 J nominal into 50 ohm load)
Pediatric Defibrillation Peak current: 19 A (50 J nominal into 50 ohm load) with optional infant/child pads
Shock-to-Shock Time Typically less than 20 seconds
Quick Shock Capability 8 seconds after end of CPR interval

User Interface

Feature Details
Voice Guidance Clear, calm step-by-step voice instructions in English (other languages available)
CPR Coaching Voice instructions for adult and pediatric CPR
CPR Metronome Audible rhythm guide for compression rate
Visual Indicators Ready light (green), Caution light (amber), Blue i-button
Controls Green On/Off button, Blue i-button, Orange Shock button, Green SMART Pads cartridge handle

Power & Battery

Specification Details
Battery Type Lithium Manganese Dioxide (LiMnO2) M5070A
Battery Life 4 years standby or 200 shocks (whichever comes first)
Battery Warranty 4 years from installation
Low Battery Alert Audible and visual warnings

Pads/Electrodes

Specification Details
Adult Pads (Included) M5071A HeartStart OnSite/Home Adult SMART Pads Cartridge
Pediatric Pads (Optional) M5072A HeartStart OnSite Infant/Child SMART Pads Cartridge
Pads Shelf Life 2 years from date of manufacture
Pads Warranty Warranted until expiration date
Pads Configuration Pre-connected to AED, cartridge-based system

Self-Testing & Readiness

Feature Details
Daily Self-Test Battery, electronics, pads presence
Weekly Self-Test Full systems check
Monthly Self-Test Comprehensive diagnostic
Ready Indicator Visible green light confirms readiness
Service Alert Caution light and beeping if service needed

Environmental Specifications

Specification Operating Standby
Temperature 32°F to 122°F (0°C to 50°C) 32°F to 140°F (0°C to 60°C)
Humidity 5% to 95% relative humidity (non-condensing) 5% to 95% relative humidity (non-condensing)
Altitude 0 to 15,000 ft (0 to 4,572 m) 0 to 15,000 ft (0 to 4,572 m)
Shock/Vibration Meets IEC 60068-2-6 and -27 Meets IEC 60068-2-6 and -27

Regulatory & Compliance

Certification Status
FDA Approval ✓ FDA-approved Class III medical device
AHA/ECC Guidelines ✓ Compliant with latest AHA/ECC guidelines
CE Mark ✓ European certification
Canadian CSA ✓ Certified for Canadian markets
IEC Standards ✓ Meets IEC 60601-1, IEC 60601-2-4
EMC Compliance ✓ IEC 60601-1-2 electromagnetic compatibility

Data & Connectivity

Feature Details
Event Data Storage Records event data for post-incident review
Data Transfer Via infrared port to HeartStart Event Review Pro software
Recorded Information ECG data, shock delivery, timing, voice prompts

Warranty Coverage

Component Warranty Period
AED Unit 8 years from date of purchase
Battery 4 years from installation
Pads Cartridge Until printed expiration date
Accessories 1 year from date of purchase

Step-by-Step Guide to Using Your Philips OnSite AED

The Philips HeartStart OnSite AED is designed to be used by anyone, even without medical training. The device will guide you through the entire process with clear voice instructions.

Step 1: Turn On the AED

  1. Press the green On/Off button
  2. The AED will immediately begin providing voice instructions
  3. Follow the voice prompts exactly as given

Step 2: Prepare the Patient

  1. Ensure the patient is on a firm, dry surface
  2. Expose the patient's bare chest
  3. Wipe chest dry if wet or sweaty
  4. Remove any medication patches if present
  5. If patient has a pacemaker or implanted defibrillator, place pads at least 1 inch away

Step 3: Apply the Pads

  1. Pull the green tab on the SMART Pads cartridge
  2. Remove the pads from the cartridge
  3. Place one pad on upper right chest (below collarbone)
  4. Place second pad on lower left side (below and to the left of nipple)
  5. Follow the diagram shown on the pads themselves
  6. Press pads firmly to ensure good contact

For Infants/Children (Under 8 years or 55 lbs):

  • Use optional M5072A Infant/Child SMART Pads Cartridge
  • Place one pad on center of chest, one on center of back
  • Follow the diagrams on pediatric pads

Step 4: Let the AED Analyze

  1. The AED will say "Don't touch the patient, analyzing heart rhythm"
  2. Ensure no one is touching the patient
  3. The AED analyzes the patient's heart rhythm automatically
  4. This takes just a few seconds

Step 5: Stand Clear for Shock (If Advised)

  1. If a shock is needed, the AED will say "Shock advised, charging"
  2. The orange Shock button will illuminate
  3. Clear the area—ensure no one is touching the patient
  4. Loudly say "Stand clear!" to warn others
  5. Press the orange Shock button when prompted
  6. The shock is delivered instantly

Step 6: Perform CPR

  1. After shock delivery (or if no shock advised), the AED will instruct you to begin CPR
  2. Follow the voice prompts for proper CPR technique
  3. The device provides a metronome to guide compression rate
  4. Continue CPR for 2 minutes or as instructed
  5. The AED will automatically reanalyze after the CPR period

Step 7: Continue Until Help Arrives

  1. Continue following the AED's voice instructions
  2. Repeat the analyze-shock-CPR cycle as needed
  3. Do not turn off the AED until emergency medical services arrive
  4. Leave the pads attached to the patient
  5. Provide arriving EMS with the AED for data review

Important Safety Notes:

  • ⚠️ Do not use AED in standing water or heavy rain
  • ⚠️ Remove all jewelry and metal objects from chest area
  • ⚠️ Do not use AED on children under 1 year without pediatric pads
  • ⚠️ Do not place pads directly over pacemakers or medication patches
  • ⚠️ Ensure no one touches patient during rhythm analysis or shock delivery

Training & Certification for Your OnSite AED

While the Philips HeartStart OnSite AED is designed for use with minimal training, proper AED and CPR certification significantly increases confidence and effectiveness during emergencies.

Recommended Training Programs

American Heart Association (AHA) Heartsaver® CPR AED

  • Comprehensive training in CPR and AED use
  • 2-year certification
  • Hands-on practice with AED trainers
  • [Learn more about AHA CPR/AED certification] [Link to training page]

American Red Cross First Aid/CPR/AED

  • Combined first aid, CPR, and AED training
  • 2-year certification
  • Online, blended, or classroom options
  • [Find a Red Cross training near you] [Link to training page]

ASHI/MEDIC First Aid®

  • Nationally recognized certification
  • Corporate training programs available
  • Flexible scheduling options
  • [Contact us for group training] [Link to contact form]

Free Resources

Online Video Training Philips offers free online video resources showing proper AED use:

  • Basic operation and pad placement
  • Pediatric considerations
  • Maintenance and troubleshooting
  • [Watch training videos] [Link to resources]

Training Mode Convert your OnSite AED to training mode with SMART Training Pads Cartridge (sold separately):

  • Practice without risk to device
  • Realistic voice prompts
  • No actual shock delivered
  • Perfect for workplace training sessions

Quick Reference Materials

  • Downloadable quick start guide
  • Printable CPR reminder cards
  • Wall poster for your AED location
  • [Download free resources] [Link to resources]

Group Training Services

On-Site Corporate Training We partner with certified instructors to provide:

    • On-location training at your facility
    • Customized to your industry needs
    • Group discounts for 10+ participants
    • Training completion certificates

Meeting AED Regulations & Protection

Federal Requirements

FDA Medical Device Classification The Philips HeartStart OnSite AED (M5066A) is FDA-approved as a Class III medical device, ensuring it meets the highest safety and efficacy standards for life-saving equipment.

Prescription Requirement As a Class III medical device, AEDs require a prescription under federal law. Hero LifeCare provides a physician's prescription with every OnSite AED purchase at no additional cost, making your acquisition fully compliant.

AHA/ECC Guideline Compliance This AED complies with the latest American Heart Association (AHA) and Emergency Cardiovascular Care (ECC) guidelines for automated external defibrillators and CPR protocols.

State & Local Requirements

Good Samaritan Laws All 50 states have Good Samaritan laws that provide legal protection for individuals who use an AED during an emergency. Key protections include:

  • Immunity from liability when acting in good faith
  • Protection for businesses that maintain AEDs
  • Exemption from medical negligence claims
  • Coverage for both trained and untrained users

State-Specific AED Laws Requirements vary by state and may include:

  • AED registration with local EMS or health department
  • Employee notification of AED location
  • Periodic training requirements
  • Medical oversight by licensed physician
  • Regular maintenance and inspections

[Check your state's AED requirements] [Link to state law database]

Workplace Requirements

OSHA Guidelines While OSHA doesn't mandate AEDs for most workplaces, the agency strongly recommends:

  • AEDs in worksites where cardiac arrest is likely (electrical work, remote locations)
  • Written AED program with maintenance protocols
  • Employee training and awareness
  • Integration with emergency response plans

Industry-Specific Requirements

Certain industries may have mandatory AED requirements:

  • Aviation: FAA requires AEDs on commercial aircraft
  • Fitness Centers: Many states require AEDs at gyms and health clubs
  • Schools: Increasing number of states mandate AEDs in schools
  • Public Buildings: Some localities require AEDs in government buildings
  • Sports Venues: Required at many organized sports facilities

AED Program Compliance Checklist

Purchase & Installation

  • Obtain AED with physician prescription (provided)
  • Register AED with local EMS (if required in your area)
  • Install in accessible, visible location
  • Post appropriate AED signage

Training & Awareness

  • Provide CPR/AED training to key staff members
  • Inform all employees of AED location
  • Conduct periodic refresher training
  • Update staff when personnel changes occur

Maintenance & Documentation

  • Check Ready indicator daily or weekly
  • Maintain log of inspections
  • Replace pads and battery before expiration
  • Keep maintenance records for compliance

Emergency Response Plan

  • Integrate AED into emergency action plan
  • Designate trained responders
  • Post clear instructions at AED location
  • Coordinate with local EMS

Medical Oversight (if required in your state)

  • Establish relationship with overseeing physician
  • Review and approve emergency response protocols
  • Update protocols based on AHA/ECC guidelines

Post-Incident Requirements

After an AED is used in an emergency:

  1. Do Not Remove Pads - Leave pads attached for EMS data review
  2. Report Use - Notify local EMS and file incident report (if required)
  3. Data Review - Download event data using Philips Event Review Pro
  4. Replace Consumables - Install new pads and battery if needed
  5. Restock - Replace any used rescue supplies
  6. Documentation - Maintain records of incident per state law

Liability Protection

Federal Cardiac Arrest Survival Act (CASA) Provides liability protection for AED acquirers and users who:

  • Have obtained appropriate training
  • Maintain and test AED according to manufacturer guidelines
  • Notify local EMS of AED acquisition
  • Comply with state and local AED requirements

Additional Protections

    • Medical device liability covered by manufacturer (Philips)
    • Good Samaritan immunity when acting in good faith
    • Business liability protection when following proper protocols
    • Reduced negligence risk with documented training and maintenance

Where to Place Your Philips HeartStart OnSite AED

The OnSite AED is ideal for any environment where sudden cardiac arrest could occur. Strategic placement ensures rapid access during emergencies.

Perfect For These Locations:

Corporate Offices & Business Parks

  • Reception areas and lobbies
  • Multi-story office buildings
  • Manufacturing facilities
  • Warehouses and distribution centers
  • Remote work locations
  • Call centers with large staff

Schools & Educational Institutions

  • Main office or nurse's station
  • Gymnasiums and athletic facilities
  • Cafeterias and common areas
  • Large classrooms or lecture halls
  • School buses (portable units)
  • Dormitories and student housing

Fitness & Recreation

  • Gyms and fitness centers
  • Swimming pools and aquatic centers
  • Golf courses and country clubs
  • Sports facilities and stadiums
  • Yoga and dance studios
  • Recreation centers

Retail & Hospitality

  • Shopping malls and retail stores
  • Hotels and resorts
  • Restaurants and food service
  • Convention centers
  • Entertainment venues
  • Casinos and gaming facilities

**Healthcare (Non-Clinical)

  • Medical office buildings
  • Dental offices
  • Outpatient clinics
  • Senior living facilities
  • Rehabilitation centers
  • Health administration offices

Public Safety & Government

  • Police and fire stations
  • City halls and government buildings
  • Libraries and community centers
  • DMV and public service offices
  • Parks and public spaces
  • Transit stations and airports

Religious Organizations

  • Churches and places of worship
  • Fellowship halls
  • Religious education buildings
  • Youth activity centers
  • Large sanctuary spaces

Industrial & Construction

  • Construction sites
  • Factory floors
  • Utility plants
  • Mining operations
  • Oil and gas facilities
  • Remote work camps

AED Placement Guidelines

Accessibility

  • Within 90 seconds' reach from anywhere in facility
  • Clearly visible or well-marked with signage
  • Not locked or requiring special access
  • Accessible during all hours of operation

Environmental Considerations

  • Protected from extreme temperatures
  • Away from direct sunlight
  • Not in damp or humid locations
  • Secure from theft or tampering
  • Near high-risk or high-traffic areas

Optimal Placement Locations

  • Near main entrances or reception desks
  • Adjacent to areas with strenuous activity
  • In or near security/safety equipment stations
  • Alongside fire extinguishers and first aid kits
  • Near elevators on each floor (multi-story buildings)

Coverage Recommendations

  • Small facility (under 5,000 sq ft): 1 AED
  • Medium facility (5,000-20,000 sq ft): 2-3 AEDs
  • Large facility (over 20,000 sq ft): 1 AED per 20,000 sq ft
  • Multi-story: At least 1 AED per floor
  • High-risk areas: Additional AED regardless of coverage

AED Storage Solutions

We offer complete AED storage and visibility solutions:

  • Wall-Mounted Cabinets - Protective, climate-controlled [Link to cabinets]
  • AED Signs & Decals - Improve visibility and compliance [Link to signage]
  • Mobile Carry Cases - For portable or traveling AEDs
  • Alarmed Cabinets - Alert staff when AED is accessed

Industry-Leading Warranty Coverage & Support for Philips AED

Comprehensive Warranty Protection

8-Year AED Warranty Philips provides an exceptional 8-year warranty on the HeartStart OnSite AED (M5066A), covering:

  • Defects in materials and workmanship
  • Electronics and internal components
  • Housing and controls
  • Software and firmware

4-Year Battery Warranty The included M5070A battery is warranted for 4 years from the date of installation:

  • Full replacement if battery fails during warranty period
  • Covers manufacturing defects
  • Prorated replacement after warranty expires

Pads Warranty Adult SMART Pads Cartridges (M5071A) are warranted until their printed expiration date:

  • Typically 2 years from date of manufacture
  • Full replacement if defective
  • Quality guarantee

Accessories Warranty All included accessories carry a 1-year warranty:

  • Carry case
  • Documentation
  • Quick reference materials

What's Not Covered

The warranty does not cover:

  • Damage from misuse or abuse
  • Environmental damage beyond specifications
  • Unauthorized modifications or repairs
  • Normal wear and tear
  • Consumables past expiration date
  • Damage from improper storage

Extended Protection Options

Extended Warranty Plans Consider additional coverage for complete peace of mind:

  • Extended 10-Year Coverage - Full protection beyond standard warranty
  • Advance Exchange Program - Replacement unit shipped immediately
  • Priority Support - Direct access to technical specialists

Customer Support

24/7 Technical Support

  • Toll-free support hotline: 1-800-256-7970
  • Email support: support@herolifecare.com
  • Average response time: Under 2 hours

Resources & Documentation

  • Downloadable owner's manuals
  • Video tutorials and training materials
  • Maintenance guides and checklists
  • Troubleshooting resources
  • Software updates

Replacement Parts & Service

  • Genuine Philips replacement parts
  • Fast shipping (next-day available)
  • Expert installation guidance
  • Trade-in programs for upgrades

AED Program Management Optional program management services:

  • Automated expiration reminders
  • Compliance tracking and documentation
  • Medical oversight coordination
  • Training coordination
HeartStart OnSite AED FAQs
  • How does the Philips HeartStart OnSite AED work?

    The AED analyzes the patient's heart rhythm and advises the user on whether a shock is necessary, while also guiding through CPR techniques.

  • Can the HeartStart OnSite be used on children?

    Yes, the integrated SMART Pads and settings allow the device to be safely used on infants, children, and adults.

  • How often does the AED conduct self-tests?

    The HeartStart OnSite performs over 80 self-tests daily to ensure operational readiness.

  • Is training required for using the HeartStart OnSite?

    While training is beneficial, the device's guided audio instructions make it easy for untrained individuals to use in emergency situations.

  • What is the warranty on the Philips HeartStart OnSite AED?

    The HeartStart OnSite comes with an 8-year manufacturer's warranty.

  • How long does the battery last for Philips AED?

    The lithium battery pack included with the device lasts for up to 4 years.

  • Can this AED be used in noisy environments?

    Yes, the AED's audio prompts are designed to be clear and audible even in noisy conditions.